Abstract
A growing number of materials and environmental settings are studied using the carbonate clumped isotope (δ47) thermometer. The method has been applied in both biogenic and non-biogenic carbonate systems, in marine and terrestrial settings, over a wide range of geological timescales. The current δ47 temperature calibration gives good temperature estimates for most biogenic materials, however, systematic biases are commonly observed at low temperatures.In this study we report additional calibration data, that covers a wider temperature range, at more evenly distributed temperatures, and are measured at higher analytical precision than the original calibration. Combining these data with the original calibration yields a δ47-T relationship that is similar to the original calibration, though slightly less steep: δ47 = (0.0526 ± 0.0025) × 106/T2 + (0.0520 ± 0.0284). This revised calibration is in better agreement with biogenic carbonates, including those grown at low temperatures. The difference between the original and revised calibrations is significant for carbonates forming below 16°C or above 49°C (δ47 values of 0.68‰ and 0.56‰). Additionally, we include a comprehensive analysis of the sources of error associated with δ47 measurements and estimated temperatures and recommend measurement strategies for obtaining the desired precision.As an illustration, we apply the revised calibration and uncertainty analysis to 3 previously published studies. At low temperatures, the revised calibration results in significant differences from the original calibration and hence affects the interpretation of the environmental signal recorded. In light of our δ47 errors analysis, in cases where the temperature signals are small, we find that replicate analyses are critical to identify a temperature signal.
Original language | English |
---|---|
Pages (from-to) | 47-57 |
Number of pages | 11 |
Journal | Earth and Planetary Science Letters |
Volume | 382 |
DOIs | |
State | Published - 15 Nov 2013 |
Externally published | Yes |
Bibliographical note
Funding Information:Shikma Zaarur and Hagit Affek designed and executed the calibration measurements and Mark Brandon contributed the statistical analysis. We thank the editor and reviewers for their insights and helpful comments; Tobias Kluge, Casey Saenger, Peter Douglas, and Brian Goldstein for fruitful discussion; technical support of Gerard Olack, Dominic Colosi, Glendon Husinger of the Earth System Center for Stable Isotope Studies. The work was supported by the National Science Foundation Grant NSF-EAR-0842482 to Hagit Affek.
Keywords
- Carbonates
- Clumped isotopes
- Thermometer calibration