TY - JOUR
T1 - Assessing the Current Generation of Tourniquets
AU - Katsnelson, Shimon
AU - Oppenheimer, Jessie
AU - Gerrasi, Rafi
AU - Furer, Ariel
AU - Wagnert-Avraham, Linn
AU - Eisenkraft, Arik
AU - Nachman, Dean
N1 - Publisher Copyright:
© 2020 Association of Military Surgeons of the United States 2020. All rights reserved.
PY - 2020/3/2
Y1 - 2020/3/2
N2 - Tourniquet application is an urgent life-saving procedure. Previous studies demonstrated several drawbacks in tourniquet design and application methods that limit their efficacy; among them, loose application of the device before windlass twisting is a main pitfall. A new generation of modern combat tourniquets was developed to overcome these pitfalls. The objective of this study was to assess the effectiveness of three new tourniquet designs: the CAT Generation 7 (CAT7), the SAM Extremity Tourniquet (SAM-XT), and the SOF Tactical Tourniquet Wide (SOFTT-W) as well as its correlation to the degree of slack. Materials and Methods: The three tourniquet models were applied in a randomized sequence on a HapMed leg tourniquet trainer, simulating an above-the-knee traumatic amputation by 60 military medicine track cadets. Applied pressure, hemorrhage control status, time until the bleeding stopped, estimated blood volume loss, and slack were measured. Results: The mean (±SD) pressure applied using the SAM-XT (186 mmHg ±63) or the CAT7 (175 mmHg ±79) was significantly higher compared to the pressure applied by the SOFTT-W (104 mmHg ±101, P < 0.017), with no significant difference between the first two (P > 0.05). Hemorrhage control rate was similar (P > 0.05) with SAM-XT (73.3%) and CAT7 (67.7%), and both were significantly better than the SOFTT-W (35%, P < 0.017). Slack was similar between CAT7 and SAM-XT (5.2 mm ± 3.4 vs. 5 mm ± 3.5, P > 0.05), yet significantly lower compared to the SOFTT-W (9 mm ± 5, P < 0.017). A strong negative correlation was found between slack and hemorrhage control rate (3.2 mm ± 1.5 mm in success vs. 10.5 mm ± 3.4 mm in failure, P < 0.001) and applied pressure (Pearson's correlation coefficient of -0.83, P < 0.001). Conclusions: Both SAM-XT and CAT7 demonstrated a better pressure profile and hemorrhage control rate compared to SOFTT-W, with no significant difference between the two. The better outcome measures were strongly correlated to less slack.
AB - Tourniquet application is an urgent life-saving procedure. Previous studies demonstrated several drawbacks in tourniquet design and application methods that limit their efficacy; among them, loose application of the device before windlass twisting is a main pitfall. A new generation of modern combat tourniquets was developed to overcome these pitfalls. The objective of this study was to assess the effectiveness of three new tourniquet designs: the CAT Generation 7 (CAT7), the SAM Extremity Tourniquet (SAM-XT), and the SOF Tactical Tourniquet Wide (SOFTT-W) as well as its correlation to the degree of slack. Materials and Methods: The three tourniquet models were applied in a randomized sequence on a HapMed leg tourniquet trainer, simulating an above-the-knee traumatic amputation by 60 military medicine track cadets. Applied pressure, hemorrhage control status, time until the bleeding stopped, estimated blood volume loss, and slack were measured. Results: The mean (±SD) pressure applied using the SAM-XT (186 mmHg ±63) or the CAT7 (175 mmHg ±79) was significantly higher compared to the pressure applied by the SOFTT-W (104 mmHg ±101, P < 0.017), with no significant difference between the first two (P > 0.05). Hemorrhage control rate was similar (P > 0.05) with SAM-XT (73.3%) and CAT7 (67.7%), and both were significantly better than the SOFTT-W (35%, P < 0.017). Slack was similar between CAT7 and SAM-XT (5.2 mm ± 3.4 vs. 5 mm ± 3.5, P > 0.05), yet significantly lower compared to the SOFTT-W (9 mm ± 5, P < 0.017). A strong negative correlation was found between slack and hemorrhage control rate (3.2 mm ± 1.5 mm in success vs. 10.5 mm ± 3.4 mm in failure, P < 0.001) and applied pressure (Pearson's correlation coefficient of -0.83, P < 0.001). Conclusions: Both SAM-XT and CAT7 demonstrated a better pressure profile and hemorrhage control rate compared to SOFTT-W, with no significant difference between the two. The better outcome measures were strongly correlated to less slack.
UR - http://www.scopus.com/inward/record.url?scp=85084392752&partnerID=8YFLogxK
U2 - 10.1093/milmed/usz392
DO - 10.1093/milmed/usz392
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 32091602
AN - SCOPUS:85084392752
SN - 0026-4075
VL - 185
SP - e377-e382
JO - Military Medicine
JF - Military Medicine
IS - 3-4
ER -