Assessing visual function behind cataract: Preoperative predictive value of the Heine Lambda 100 retinometer

Michael Mimouni, Yinon Shapira, Janan Jadon, Shahar Frenkel, Eytan Z. Blumenthal*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

Purpose: To analyze the accuracy of the Lambda 100 (Heine) potential visual acuity (VA) measurements in subjects undergoing cataract surgery. Methods: The medical records of all consecutive patients who underwent clear corneal incision phacoemulsification cataract surgery by a single surgeon between 2010 and 2012 at the Department of Ophthalmology, Hadassah Medical Center, a tertiary care hospital in Jerusalem, Israel, were reviewed. Subjects age 18 or older with a followup time of at least 30 days were included. Subjects with previous ocular comorbidities other than glaucoma were excluded. In addition, patients with intraoperative or perioperative complications that could affect final VA were excluded. Analyses were performed to analyze the accuracy of preoperative retinometer potential VA as a predictor of postoperative best-corrected VA. Results: A total of 374 operated eyes were included. There was a moderate positive correlation between Lambda estimated VA potential and postoperative achieved best-corrected VA (BCVA) (β coefficient 0.35, p<0.0001). Overall Lambda accurately (within 2 Snellen lines) estimated postoperative BCVA results in 60% of cases. The accuracy of prediction was significantly better in moderate cataracts when compared with advanced cataracts (p<0.01) with a twofold tendency towards underestimation in advanced cataracts. A Lambda ≥0.5 decimal has a calculated positive predictive value of 82% and a negative predictive value of 40% for predicting postoperative BCVA outcome ≥0.5 decimal. Conclusions: Lambda may be used to relatively accurately predict postoperative BCVA in cataract patients, specifically in those with moderate cataracts.

Original languageEnglish
Pages (from-to)559-564
Number of pages6
JournalEuropean Journal of Ophthalmology
Volume27
Issue number5
DOIs
StatePublished - 1 Sep 2017
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2017 Wichtig Publishing.

Keywords

  • Cataract
  • Lambda
  • Retinometer
  • Surgery
  • Visual acuity

Fingerprint

Dive into the research topics of 'Assessing visual function behind cataract: Preoperative predictive value of the Heine Lambda 100 retinometer'. Together they form a unique fingerprint.

Cite this