Automatic endocardial-boundary detection in low mechanical-index contrast echocardiography

Gil Zwirn*, Ronen Beeri, Dan Gilon, Solange Akselrod

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

11 Scopus citations

Abstract

This paper presents a novel algorithm, aimed at automatic endocardial boundary (inner boundary) detection in myocardial opacification scenarios. The data acquisition protocol uses (on purpose) low mechanical index imaging (i.e., weak ultrasound signal), so that the acquired images are characterized by low signal-to-noise ratios. The proposed algorithm is based on converting the frames, given in Cartesian coordinates, into polar coordinates, and applying a set of filters in order to compute the initial estimation of the endocardial boundary. The final estimation of the endocardial boundary is produced by an error correction process, which uses both spatial and temporal filtering. The estimated boundaries are converted into Cartesian coordinates, for display. Our algorithm has been tested on nine cine-loops. The resulting myocardial outlines have been separately assessed by two clinicians, scoring each segment in each cine-loop on a scale between 5 (excellent) and 1 (completely unacceptable). The mean overall score is 3.8 ± 0.8, which seems adequate. The same clinicians have also manually drawn the contours of the endocardial boundary for the end-systolic and the end-diastolic frames of each cine-loop. The results show, that the mismatch between the automatically determined outlines and the manually drawn outlines is of the same order of magnitude as the interobserver variability. These results further support the validity of our method.

Original languageEnglish
Pages (from-to)2310-2322
Number of pages13
JournalIEEE Transactions on Biomedical Engineering
Volume53
Issue number11
DOIs
StatePublished - Nov 2006
Externally publishedYes

Bibliographical note

Funding Information:
Manuscript received January 29, 2005; revised May 6, 2006. This work was supported in part by the Israeli Ministry of Commerce and Industry under Grant “Nophar”, and in part by The Ela Kodesh Fund for Biomedical Engineering, Tel Aviv University. Asterisk indicates corresponding author. *G. Zwirn is with the Abramson Center of Medical Physics, Sackler Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 69978, Israel (e-mail: [email protected]).

Keywords

  • Contrast agents
  • Echocardiography
  • Myocardial perfusion
  • Outline detection

Fingerprint

Dive into the research topics of 'Automatic endocardial-boundary detection in low mechanical-index contrast echocardiography'. Together they form a unique fingerprint.

Cite this