T1 - Characterisation of trocar associated gas leaks during laparoscopic surgery
AU - the Technology committee of the European Association for Endoscopic Surgery (EAES)
AU - Robertson, Daniel
AU - Sterke, Frank
AU - van Weteringen, Willem
AU - Arezzo, Alberto
AU - Mintz, Yoav
AU - Nickel, Felix
AU - Boni, Luigi
AU - Baldari, Ludovica
AU - Carus, Thomas
AU - Chand, Manish
AU - Fuchs, Hans
AU - Ficuciello, Fanny
AU - Marconi, Stefania
AU - Mylonas, George
AU - Kim, Young Woo
AU - Nakajima, Kiyokazu
AU - Schijven, Marlies
AU - Valdastri, Pietro
AU - Sagiv, Chen
AU - Mascagni, Pietro
AU - Myśliwiec, Piotr
AU - Petz, Wanda
AU - Sánchez-Margallo, Francisco
AU - Horeman, Tim
N1 - Publisher Copyright:
© 2021, The Author(s).
PY - 2022/6
Y1 - 2022/6
N2 - Background: During laparoscopy, the abdominal cavity is insufflated with carbon dioxide (CO2) that could become contaminated with viruses and surgical smoke. Medical staff is potentially exposed when this gas leaks into the operating room through the instruments and past trocar valves. No detailed studies currently exist that have quantified these leakage pathways. Therefore, the goal of this study was to quantify the gas leakages through trocars and instruments, during minimally invasive procedures. Methods: A model of the surgical environment was created, consisting of a rigid container with an interface for airtight clamping of laparoscopic equipment such as trocars and surgical instruments. The model was insufflated to 15 mm Hg using a pressure generator and a pneumotachograph measured the equipment gas leak. A protocol of several use cases was designed to simulate the motions and forces the surgeon exerts on the trocar during surgery. Results: Twenty-three individual trocars and twenty-six laparoscopic instruments were measured for leakage under the different conditions of the protocol. Trocar leakages varied between 0 L/min and more than 30 L/min, the instruments revealed a range of leakages between 0 L/min and 5.5 L/min. The results showed that leakage performance varied widely between trocars and instruments and that the performance and location of the valves influenced trocar leakage. Conclusions: We propose trocar redesigns to overcome specific causes of gas leaks. Moreover, an international testing standard for CO2 leakage for all new trocars and instruments is needed so surgical teams can avoid this potential health hazard when selecting new equipment.
AB - Background: During laparoscopy, the abdominal cavity is insufflated with carbon dioxide (CO2) that could become contaminated with viruses and surgical smoke. Medical staff is potentially exposed when this gas leaks into the operating room through the instruments and past trocar valves. No detailed studies currently exist that have quantified these leakage pathways. Therefore, the goal of this study was to quantify the gas leakages through trocars and instruments, during minimally invasive procedures. Methods: A model of the surgical environment was created, consisting of a rigid container with an interface for airtight clamping of laparoscopic equipment such as trocars and surgical instruments. The model was insufflated to 15 mm Hg using a pressure generator and a pneumotachograph measured the equipment gas leak. A protocol of several use cases was designed to simulate the motions and forces the surgeon exerts on the trocar during surgery. Results: Twenty-three individual trocars and twenty-six laparoscopic instruments were measured for leakage under the different conditions of the protocol. Trocar leakages varied between 0 L/min and more than 30 L/min, the instruments revealed a range of leakages between 0 L/min and 5.5 L/min. The results showed that leakage performance varied widely between trocars and instruments and that the performance and location of the valves influenced trocar leakage. Conclusions: We propose trocar redesigns to overcome specific causes of gas leaks. Moreover, an international testing standard for CO2 leakage for all new trocars and instruments is needed so surgical teams can avoid this potential health hazard when selecting new equipment.
KW - Carbon dioxide
KW - Gas leak
KW - Laparoscopic equipment
KW - Surgical safety
KW - Surgical smoke
UR - https://www.scopus.com/pages/publications/85129246765
U2 - 10.1007/s00464-021-08807-1
DO - 10.1007/s00464-021-08807-1
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 34731302
AN - SCOPUS:85129246765
SN - 0930-2794
VL - 36
SP - 4542
EP - 4551
JO - Surgical Endoscopy
JF - Surgical Endoscopy
IS - 6
ER -