Comparison of body composition assessment across body mass index categories by two multifrequency bioelectrical impedance analysis devices and dual-energy X-ray absorptiometry in clinical settings

  • Yair Lahav
  • , Nir Goldstein
  • , Yftach Gepner*
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

66 Scopus citations

Abstract

Background: InBody-770 and SECA mBCA 515 are multifrequency bioelectrical impedance analysis (BIA) devices, which are commonly used in the clinic to assess fat-free mass (FFM) and body fat (BF). However, the accuracy between devices in clinical settings, across different body mass index (BMI) groups remains unclear. Methods: Body composition for 226 participants (51% men, aged 18–80 years, BMI 18–56 kg/m²) was assessed by two commercial multifrequency BIA devices requiring standing position and using eight-contact electrodes, InBody 770 and SECA mBCA 515, and compared to results from dual-energy X-ray absorptiometry (DXA). Measurements were performed in a random order, after a 3 h fast and no prior exercise. Lin’s-concordance correlation and Bland–Altman analyses were used to compare between devices, and linear regression to assess accuracy in BF% across BMI groups. Results: We found strong correlation between DXA results for study population BF% and those obtained by InBody (ρc = 0.922, 95% confidence interval (CI) 0.902, 0.938) and DXA and SECA (ρc = 0.940, CI 0.923, 0.935), with 95% limits of agreements between 2.6 and −8.9, and 7.1 and −7.6, respectively. BF% assessment by SECA was similar to DXA (−0.3%, p = 0.267), and underestimated by InBody (−3.1%, p < 0.0001). InBody deviations were largest among normal weight people and decreased with increasing BMI group, while SECA measurements remained unaffected. Conclusions: Both BIA devices agreed well with BF% assessment obtained by DXA. Unlike SECA, InBody underestimated BF% in both genders and was influenced by BMI categories. Therefore, in clinical settings, individual assessment of BF% should be taken with caution.

Original languageEnglish
Pages (from-to)1275-1282
Number of pages8
JournalEuropean Journal of Clinical Nutrition
Volume75
Issue number8
DOIs
StatePublished - Aug 2021
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2021, The Author(s), under exclusive licence to Springer Nature Limited part of Springer Nature.

Fingerprint

Dive into the research topics of 'Comparison of body composition assessment across body mass index categories by two multifrequency bioelectrical impedance analysis devices and dual-energy X-ray absorptiometry in clinical settings'. Together they form a unique fingerprint.

Cite this