Abstract
This paper presents a mathematical-statistical method to help evaluate the temperature effect on BOD and SS residual ratio during and after a trickling filter plant treatment. Mathematical relationships are developed and brought to workable linear forms which are then used for statistical examination by the F test method. The data for this purpose is provided by regular measurements of wastewater quality in a full-scale treatment plant. While settling performance did not respond consistently to temperature changes, the secondary treatment and the overall plant performance provided good correlations with the correct representative temperatures.
| Original language | English |
|---|---|
| Pages (from-to) | 53-67 |
| Number of pages | 15 |
| Journal | Water Science and Technology |
| Volume | 17 |
| Issue number | 2-3 -3 pt 1 |
| DOIs | |
| State | Published - 1985 |