TY - JOUR
T1 - Experimentally quantifying the advantages of weak-value-based metrology
AU - Viza, Gerardo I.
AU - Martínez-Rincón, Julián
AU - Alves, Gabriel B.
AU - Jordan, Andrew N.
AU - Howell, John C.
N1 - Publisher Copyright:
© 2015 American Physical Society.
PY - 2015/9/22
Y1 - 2015/9/22
N2 - We experimentally investigate the relative advantages of implementing weak-value-based metrology versus standard methods. While the techniques outlined herein apply more generally, we measure small optical beam deflections both using a Sagnac interferometer with a monitored dark port (the weak-value-based technique), and by focusing the entire beam to a split detector (the standard technique). By introducing controlled external transverse detector modulations and transverse beam deflection momentum modulations, we quantify the mitigation of these sources in the weak-value-based experiment versus the standard focusing experiment. The experiments are compared using a combination of deterministic and stochastic methods. In all cases, the weak-value technique performs the same or better than the standard technique by up to two orders of magnitude in precision for our parameters. We further measure the statistical efficiency of the weak-value-based technique. By postselecting on 1% of the photons, we obtain 99% of the available Fisher information of the beam deflection parameter.
AB - We experimentally investigate the relative advantages of implementing weak-value-based metrology versus standard methods. While the techniques outlined herein apply more generally, we measure small optical beam deflections both using a Sagnac interferometer with a monitored dark port (the weak-value-based technique), and by focusing the entire beam to a split detector (the standard technique). By introducing controlled external transverse detector modulations and transverse beam deflection momentum modulations, we quantify the mitigation of these sources in the weak-value-based experiment versus the standard focusing experiment. The experiments are compared using a combination of deterministic and stochastic methods. In all cases, the weak-value technique performs the same or better than the standard technique by up to two orders of magnitude in precision for our parameters. We further measure the statistical efficiency of the weak-value-based technique. By postselecting on 1% of the photons, we obtain 99% of the available Fisher information of the beam deflection parameter.
UR - http://www.scopus.com/inward/record.url?scp=84943228060&partnerID=8YFLogxK
U2 - 10.1103/PhysRevA.92.032127
DO - 10.1103/PhysRevA.92.032127
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:84943228060
SN - 1050-2947
VL - 92
JO - Physical Review A - Atomic, Molecular, and Optical Physics
JF - Physical Review A - Atomic, Molecular, and Optical Physics
IS - 3
M1 - 032127
ER -