TY - JOUR
T1 - MitraClip detachment after electrical cardioversion
T2 - A case report
AU - Yagel, Oren
AU - Planer, David
AU - Elitzur, Yair
AU - Be'Eri, Ronen
AU - Elbaz-Greener, Gabby
N1 - Publisher Copyright:
© 2023 The Author(s).
PY - 2023/5/1
Y1 - 2023/5/1
N2 - Background: Transcatheter edge-to-edge repair (TEER) repair is a minimally invasive procedure used for patients with severe mitral regurgitation (MR). Cardioversion is indicated for haemodynamically unstable patients with narrow complex tachycardia and is generally considered safe post-mitral clip. We present a patient who underwent cardioversion post-TEER with a single leaflet detachment (SLD). Case summary: An 86-year-old female with severe MR underwent TEER with a MitraClip that reduced MR severity to mild. During the procedure, the patient experienced tachycardia, and cardioversion was performed successfully. However, immediately after the cardioversion, the operators noticed recurrent severe MR with a posterior leaflet clip detachment. Deployment of a new clip adjacent to the detached one was obtained. Discussion: Transcatheter edge-to-edge repair is a well-established method for treating severe MR in patients who are not suitable for surgical intervention. However, complications can arise during or after the procedure, such as clip detachment as in this case. Several mechanisms can explain SLD. We presumed that in the current case, immediately after cardioversion, there was an acute (post-pause) increase in left ventricle end-diastolic volume and thus in the left ventricle systolic volume with more vigorous contraction, possibly pulling apart the leaflets and detaching the freshly applied TEER device. This is the first report of SLD related to electrical cardioversion after TEER. Even though electrical cardioversion is considered safe, SLD can occur in this setting.
AB - Background: Transcatheter edge-to-edge repair (TEER) repair is a minimally invasive procedure used for patients with severe mitral regurgitation (MR). Cardioversion is indicated for haemodynamically unstable patients with narrow complex tachycardia and is generally considered safe post-mitral clip. We present a patient who underwent cardioversion post-TEER with a single leaflet detachment (SLD). Case summary: An 86-year-old female with severe MR underwent TEER with a MitraClip that reduced MR severity to mild. During the procedure, the patient experienced tachycardia, and cardioversion was performed successfully. However, immediately after the cardioversion, the operators noticed recurrent severe MR with a posterior leaflet clip detachment. Deployment of a new clip adjacent to the detached one was obtained. Discussion: Transcatheter edge-to-edge repair is a well-established method for treating severe MR in patients who are not suitable for surgical intervention. However, complications can arise during or after the procedure, such as clip detachment as in this case. Several mechanisms can explain SLD. We presumed that in the current case, immediately after cardioversion, there was an acute (post-pause) increase in left ventricle end-diastolic volume and thus in the left ventricle systolic volume with more vigorous contraction, possibly pulling apart the leaflets and detaching the freshly applied TEER device. This is the first report of SLD related to electrical cardioversion after TEER. Even though electrical cardioversion is considered safe, SLD can occur in this setting.
KW - Cardioversion
KW - Case report
KW - Clip detachment
KW - Edge-to-edge mitral repair
KW - Mitral clip
KW - Mitral regurgitation
UR - http://www.scopus.com/inward/record.url?scp=85160927807&partnerID=8YFLogxK
U2 - 10.1093/ehjcr/ytad226
DO - 10.1093/ehjcr/ytad226
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 37207107
AN - SCOPUS:85160927807
SN - 2514-2119
VL - 7
JO - European Heart Journal - Case Reports
JF - European Heart Journal - Case Reports
IS - 5
M1 - ytad226
ER -