Abstract
Multilayer Mirror (MLM) based monitors are compact, high throughput diagnostics capable of extracting XUV emissions of impurities from the harsh environment of large fusion reactor type devices. In this article, the concepts and designs of MLM based monitors for impurity controls in ITER are presented. The results of neutron irradiation experiments of the MLMs performed in the Los Alamos National Laboratory are also discussed. These preliminary neutron exposure studies show that the dispersive and reflective qualities of the MLMs are not affected in a significant manner.
Original language | English |
---|---|
Pages | 704-707 |
Number of pages | 4 |
State | Published - 1995 |
Externally published | Yes |
Event | Proceedings of the 1995 16th IEEE/NPSS Symposium on Fusion Engineering. Part 1 (of 2) - Champaign, IL, USA Duration: 1 Oct 1995 → 5 Oct 1995 |
Conference
Conference | Proceedings of the 1995 16th IEEE/NPSS Symposium on Fusion Engineering. Part 1 (of 2) |
---|---|
City | Champaign, IL, USA |
Period | 1/10/95 → 5/10/95 |