Multilayer mirror based monitors for impurity controls in large fusion reactor type devices

S. P. Regan*, M. J. May, V. Soukhanovskii, M. Finkenthal, H. W. Moos

*Corresponding author for this work

Research output: Contribution to conferencePaperpeer-review

Abstract

Multilayer Mirror (MLM) based monitors are compact, high throughput diagnostics capable of extracting XUV emissions of impurities from the harsh environment of large fusion reactor type devices. In this article, the concepts and designs of MLM based monitors for impurity controls in ITER are presented. The results of neutron irradiation experiments of the MLMs performed in the Los Alamos National Laboratory are also discussed. These preliminary neutron exposure studies show that the dispersive and reflective qualities of the MLMs are not affected in a significant manner.

Original languageEnglish
Pages704-707
Number of pages4
StatePublished - 1995
Externally publishedYes
EventProceedings of the 1995 16th IEEE/NPSS Symposium on Fusion Engineering. Part 1 (of 2) - Champaign, IL, USA
Duration: 1 Oct 19955 Oct 1995

Conference

ConferenceProceedings of the 1995 16th IEEE/NPSS Symposium on Fusion Engineering. Part 1 (of 2)
CityChampaign, IL, USA
Period1/10/955/10/95

Fingerprint

Dive into the research topics of 'Multilayer mirror based monitors for impurity controls in large fusion reactor type devices'. Together they form a unique fingerprint.

Cite this