Skip to main navigation Skip to search Skip to main content

Photography-based method for assessing fluorescein clearance test in dogs

  • Arianne Pontes Oriá*
  • , Miriam Flores Rebouças
  • , Emanoel Martins Filho
  • , Francisco de Assis Dórea Neto
  • , Ana Cláudia Raposo
  • , Lionel Sebbag
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

8 Scopus citations

Abstract

Background: The fluorescein clearance test (FCT) provides insight into the tear film dynamics. The purpose of this study was to describe an inexpensive and practical method for assessing FCT in dogs, using photography and software analysis, and to assess the retention time of 1 vs. 2 eye drops on the canine ocular surface. Methods: (i) In vivo - Eight healthy German Shepherd dogs were recruited. Following topical anesthesia with 0.5% proxymetacaine, each eye sequentially received (1 week apart) either 1 drop (35 μL) or 2 drops (70 μL) of 0.5% fluorescein. A Schirmer strip was inserted in the ventral conjunctival fornix for 10 s at the following times: each 10 min for 100 min, 24 h, 48 h and 72 h. (ii) In vitro - Schirmer strips were placed for 10 s in contact with microplate wells containing 1 or 2 drops of 0.5% fluorescein. In both experiments, the fluorescein-impregnated Schirmer strips were immediately imaged, and the area and intensity of fluorescein uptake were analyzed with ImageJ software. For the in vitro experiment, images were evaluated by the same examiner (repeatability) or two examiners (reproducibility). Results: Photography-based FCT was easy to perform and showed high repeatability and reproducibility (coefficients of variation ≤2.75%). In vivo, the area and intensity of fluorescein uptake on Schirmer strips were significantly greater at 30 min and 40 min post- fluorescein instillation in the 2 drops vs. 1 drop groups (p ≤ 0.044). Compared to baseline, the residual fluorescein uptake on Schirmer strips was < 5% at 60 min and 90 min in the 1 drop and 2 drops groups, respectively. Conclusions: Photography-based FCT is a practical and reliable diagnostic tool with various clinical and research applications in veterinary medicine. Instillation of two drops provided greater amount and longer retention on the anesthetized canine ocular surface than a single drop. Fluorescein clearance time of a single drop in dolichocephalic dogs is 60 min.

Original languageEnglish
Article number269
JournalBMC Veterinary Research
Volume14
Issue number1
DOIs
StatePublished - 3 Sep 2018
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2018 The Author(s).

Keywords

  • Dogs
  • Fluorescein clearance test
  • Schirmer tear test
  • Tear film

Fingerprint

Dive into the research topics of 'Photography-based method for assessing fluorescein clearance test in dogs'. Together they form a unique fingerprint.

Cite this