TY - JOUR
T1 - Poly(sebacic acid-co-ricinoleic acid) biodegradable carrier for paclitaxel - Effect of additives
AU - Shikanov, Ariella
AU - Ezra, Aviva
AU - Domb, Abraham J.
PY - 2005/6/20
Y1 - 2005/6/20
N2 - Injectable polymeric formulation for paclitaxel was studied. Poly ricinoleic acid and sebacic acid were synthesized. The effect of additives on the viscosity of polymer, paclitaxel release, and polymer degradation was investigated both in vitro and in vivo. Additives that were used in this study were ricinoleic acid, phospholipid, PEG 400, and PEG 2000. Addition of 20% ricinoleic acid to P(SA:RA)3:7 liquefied the formulation and allowed injection of the formulation containing paclitaxel via a 22-G needle at room temperature with no effect on paclitaxel release rate. Addition of PEG 400, PEG 2000, and phospholipid to the formulation did not affect the paclitaxel release from the formulation. The degradation of modified formulations with paclitaxel and additives was examined in vitro and by subcutaneous injection of liquid formulations to the backspace via a 22-G needle into seven groups of four C3H mice. In vivo formulations with additives (20% ricinoleic acid and PEG or phospholipid) and 5% paclitaxel content degraded faster than the formulation with only 20% ricinoleic acid and the same paclitaxel content: 51% and 54% versus 43%. The slowest degradation (26% in 1 week) was of the formulation containing 10% paclitaxel. The release rate in vivo was affected by the paclitaxel content; the higher the content, the slower was the release. By using additives, we could adjust the physical characteristics of the surgical paste while maintaining a desirable system for sustained paclitaxel release.
AB - Injectable polymeric formulation for paclitaxel was studied. Poly ricinoleic acid and sebacic acid were synthesized. The effect of additives on the viscosity of polymer, paclitaxel release, and polymer degradation was investigated both in vitro and in vivo. Additives that were used in this study were ricinoleic acid, phospholipid, PEG 400, and PEG 2000. Addition of 20% ricinoleic acid to P(SA:RA)3:7 liquefied the formulation and allowed injection of the formulation containing paclitaxel via a 22-G needle at room temperature with no effect on paclitaxel release rate. Addition of PEG 400, PEG 2000, and phospholipid to the formulation did not affect the paclitaxel release from the formulation. The degradation of modified formulations with paclitaxel and additives was examined in vitro and by subcutaneous injection of liquid formulations to the backspace via a 22-G needle into seven groups of four C3H mice. In vivo formulations with additives (20% ricinoleic acid and PEG or phospholipid) and 5% paclitaxel content degraded faster than the formulation with only 20% ricinoleic acid and the same paclitaxel content: 51% and 54% versus 43%. The slowest degradation (26% in 1 week) was of the formulation containing 10% paclitaxel. The release rate in vivo was affected by the paclitaxel content; the higher the content, the slower was the release. By using additives, we could adjust the physical characteristics of the surgical paste while maintaining a desirable system for sustained paclitaxel release.
KW - Additives
KW - Biodegradable polymer
KW - Implant
KW - Paclitaxel
KW - Poly(ester anhydride)
UR - http://www.scopus.com/inward/record.url?scp=20444408397&partnerID=8YFLogxK
U2 - 10.1016/j.jconrel.2005.02.018
DO - 10.1016/j.jconrel.2005.02.018
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 15955366
AN - SCOPUS:20444408397
SN - 0168-3659
VL - 105
SP - 52
EP - 67
JO - Journal of Controlled Release
JF - Journal of Controlled Release
IS - 1-2
ER -