TY - JOUR
T1 - Quantification of free and metal-complexed cyanide by tetrathionate derivatization
AU - Kamyshny, Alexey
AU - Oduro, Harry
AU - Farquhar, James
PY - 2012/11
Y1 - 2012/11
N2 - A sensitive and robust method for detection of free and metal-complexed cyanide in solutions is described. The method does not require a distillation step and is applicable for both low ionic strength and sea-water samples. The method is based on the reaction of cyanide with potassium tetrathionate followed by high-performance liquid chromatography (HPLC) separation and UV detection of formed thiocyanate. The detection limit of the method is 250 nmol L-1 cyanide (6.5 μg L-1 CN-) without a pre-concentration step. Storage for three days does not significantly change the results. The sum of free and weak metal-complexed cyanide can be measured by tetrathionate derivatization at a pH of 10. The sum of free, weak metal-complexed cyanide, iron(II) and iron(III)-complexed cyanides may be measured by tetrathionate derivatization at pH 4.4. Derivatization requires heating to 90°C for 20 min at pH = 10 and for 12 h at pH = 4.4. Weighted mean recoveries for free, iron(II), iron(III), nickel(II), silver(I), Cd(II) and Zn(II) complexed cyanide were in the range of 87 to 112% and weighted standard deviations were in the range of 1.7 to 10.0%. The method is not applicable for cyanide complexes of gold and cobalt. We illustrate an application of cyanide quantification using pore-waters from the Delaware Great Marsh.
AB - A sensitive and robust method for detection of free and metal-complexed cyanide in solutions is described. The method does not require a distillation step and is applicable for both low ionic strength and sea-water samples. The method is based on the reaction of cyanide with potassium tetrathionate followed by high-performance liquid chromatography (HPLC) separation and UV detection of formed thiocyanate. The detection limit of the method is 250 nmol L-1 cyanide (6.5 μg L-1 CN-) without a pre-concentration step. Storage for three days does not significantly change the results. The sum of free and weak metal-complexed cyanide can be measured by tetrathionate derivatization at a pH of 10. The sum of free, weak metal-complexed cyanide, iron(II) and iron(III)-complexed cyanides may be measured by tetrathionate derivatization at pH 4.4. Derivatization requires heating to 90°C for 20 min at pH = 10 and for 12 h at pH = 4.4. Weighted mean recoveries for free, iron(II), iron(III), nickel(II), silver(I), Cd(II) and Zn(II) complexed cyanide were in the range of 87 to 112% and weighted standard deviations were in the range of 1.7 to 10.0%. The method is not applicable for cyanide complexes of gold and cobalt. We illustrate an application of cyanide quantification using pore-waters from the Delaware Great Marsh.
KW - cyanide
KW - iron-cyanide complexes
KW - liquid chromatography
KW - metallo-cyanide complexes
KW - tetrathionate
UR - http://www.scopus.com/inward/record.url?scp=84867211281&partnerID=8YFLogxK
U2 - 10.1080/03067319.2011.561339
DO - 10.1080/03067319.2011.561339
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:84867211281
SN - 0306-7319
VL - 92
SP - 1506
EP - 1517
JO - International Journal of Environmental Analytical Chemistry
JF - International Journal of Environmental Analytical Chemistry
IS - 13
ER -