Skip to main navigation Skip to search Skip to main content

Study of impurity radiation on the PLT and TFTR tokamaks with high-resolution, time-resolving spectrometers

  • A. W. Wouters*
  • , J. L. Schwob
  • , S. Suckewer
  • , F. P. Boody
  • , R. Hulse
  • , J. Schivell
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

11 Scopus citations

Abstract

Soft-x-ray (5-300 Å) spectra of intrinsic impurities have been recorded with a high-resolution multichannel XUV spectrometer (SOXMOS). Measurements of line intensity ratios as a function of time are applied to the determination of the impurity contribution to the energy balance. Results from TFTR Ohmic heated plasmas, including radiation due to carbon, oxygen, iron, nickel, chromium, titanium, and zirconium, are presented. The spatial ion distribution will be directly observed by a radial scanning spectrometer (FLOPSY). This instrument, under construction, will cover the spectral range from 1500 to 7000 Å and use mirrors and lenses for fast scanning. The spatial ion distribution, deduced from forbidden and allowed lines, will be compared to both theoretical models based on impurity concentrations and transport coefficients, as well as experimental data from bolometer measurements.

Original languageEnglish
Pages (from-to)849-851
Number of pages3
JournalReview of Scientific Instruments
Volume56
Issue number5
DOIs
StatePublished - 1985
Externally publishedYes

Fingerprint

Dive into the research topics of 'Study of impurity radiation on the PLT and TFTR tokamaks with high-resolution, time-resolving spectrometers'. Together they form a unique fingerprint.

Cite this