236U in uranium minerals and standards

D. Berkovits, H. Feldstein, S. Ghelberg, A. Hershkowitz, E. Navon, M. Paul*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

94 Scopus citations

Abstract

We have recently extended our accelerator mass spectrometry (AMS) system to the detection of actinides for geophysical applications, taking 236U as an interesting test case for this class of nuclides. We report on the development of the experimental setup and on preliminary measurements of 236U in minerals and uranium standards. The isotopic abundance sensitivity is 1 × 10-11. The natural 236U abundance of five U-rich minerals were measured to be between 1 and 33 × 10-11. 236U is expected to be produced in situ by neutron capture on 235U. Three uranium standards material were measured and showed a large 236U contamination.

Original languageEnglish
Pages (from-to)372-376
Number of pages5
JournalNuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
Volume172
Issue number1-4
DOIs
StatePublished - 2000

Fingerprint

Dive into the research topics of '236U in uranium minerals and standards'. Together they form a unique fingerprint.

Cite this