TY - JOUR
T1 - The ED50 and ED95 of intrathecal isobaric bupivacaine with opioids for cesarean delivery
AU - Carvalho, Brendan
AU - Durbin, Marie
AU - Drover, David R.
AU - Cohen, Sheila E.
AU - Ginosar, Yehuda
AU - Riley, Edward T.
PY - 2005/9
Y1 - 2005/9
N2 - Background; The ideal intrathecal isobaric bupivacaine dose for cesarean delivery anesthesia is uncertain. While small doses (5-9 mg) of bupivacaine may reduce side effects such as hypotension, they potentially increase spinal anesthetic failures. This study determined the ED50 and ED 95 of intrathecal isobaric bupivacaine (with adjuvant opioids) for cesarean delivery. Methods: After institutional review board approval and written informed consent were obtained, 48 parturients undergoing elective cesarean delivery under combined spinal-epidural anesthesia were enrolled in this double-blind, randomized, dose-ranging study. Patients received a 5-, 6-, 7-, 8-, 9-, 10-, 11-, or 12-mg intrathecal isobaric bupivacaine dose with 10 μg fentanyl and 200 μg morphine. Overall anesthetic success was recorded when no intraoperative epidural supplement was required during the cesarean delivery. ED50 and ED95 values for overall anesthetic success were determined using a logistic regression model. Results: ED 50 and ED95 values for overall anesthetic success were 7.25 and 13.0 mg, respectively. No advantages for low doses could be demonstrated with regard to hypotension, nausea, vomiting, pruritus, or maternal satisfaction, although this study was underpowered to detect significant differences in secondary outcome variables. Conclusions: The ED50 and ED95 values (7.25 and 13.0 mg, respectively) for intrathecal isobaric bupivacaine in this circumstance are similar to values the authors determined recently for hyperbaric bupivacaine using similar methodology. These ED50 and ED95 values are significantly higher than those advocated in previous reports in which success was claimed using lower intrathecal bupivacaine doses. The current study used stricter criteria to define "successful" anesthesia and support the use of larger bupivacaine doses to ensure adequate patient comfort.
AB - Background; The ideal intrathecal isobaric bupivacaine dose for cesarean delivery anesthesia is uncertain. While small doses (5-9 mg) of bupivacaine may reduce side effects such as hypotension, they potentially increase spinal anesthetic failures. This study determined the ED50 and ED 95 of intrathecal isobaric bupivacaine (with adjuvant opioids) for cesarean delivery. Methods: After institutional review board approval and written informed consent were obtained, 48 parturients undergoing elective cesarean delivery under combined spinal-epidural anesthesia were enrolled in this double-blind, randomized, dose-ranging study. Patients received a 5-, 6-, 7-, 8-, 9-, 10-, 11-, or 12-mg intrathecal isobaric bupivacaine dose with 10 μg fentanyl and 200 μg morphine. Overall anesthetic success was recorded when no intraoperative epidural supplement was required during the cesarean delivery. ED50 and ED95 values for overall anesthetic success were determined using a logistic regression model. Results: ED 50 and ED95 values for overall anesthetic success were 7.25 and 13.0 mg, respectively. No advantages for low doses could be demonstrated with regard to hypotension, nausea, vomiting, pruritus, or maternal satisfaction, although this study was underpowered to detect significant differences in secondary outcome variables. Conclusions: The ED50 and ED95 values (7.25 and 13.0 mg, respectively) for intrathecal isobaric bupivacaine in this circumstance are similar to values the authors determined recently for hyperbaric bupivacaine using similar methodology. These ED50 and ED95 values are significantly higher than those advocated in previous reports in which success was claimed using lower intrathecal bupivacaine doses. The current study used stricter criteria to define "successful" anesthesia and support the use of larger bupivacaine doses to ensure adequate patient comfort.
UR - http://www.scopus.com/inward/record.url?scp=24144439285&partnerID=8YFLogxK
U2 - 10.1097/00000542-200509000-00025
DO - 10.1097/00000542-200509000-00025
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 16129987
AN - SCOPUS:24144439285
SN - 0003-3022
VL - 103
SP - 606
EP - 612
JO - Anesthesiology
JF - Anesthesiology
IS - 3
ER -