Skip to main navigation Skip to search Skip to main content

The shadow of the intrauterine device

  • Dan Vadim Valsky
  • , Sarah M. Cohen
  • , Drorith Hochner-Celnikier
  • , Achinoam Lev-Sagie
  • , Simcha Yagel*
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

18 Scopus citations

Abstract

Objective. An intrauterine device (IUD) is a highly effective and prevalent form of birth control with a low failure rate. It is not without complications, including irregular bleeding and pelvic pain, perforation, expulsion, and pregnancy. Investigation of the symptomatic patient and routine follow-up of asymptomatic women with IUDs include transvaginal ultrasonography to rule out IUD malposition and other complications. Three-dimensional ultrasonography (3DUS) has been shown to have added value in imaging the pelvic organs, including the uterus. However, even with 3DUS, the operator may encounter difficulty in imaging the IUD in its entirety, because of variability in both echogenicity and exact location. Methods. More than 30 women undergoing IUD placement evaluation, including routine examinations and cases of suspected pregnancy, irregular bleeding, infection, and pelvic pain, were evaluated with 3DUS and volume contrast imaging in the C plane (VCI-C), which visualized acoustic shadows of the IUDs, facilitating identification of the intrauterine position and type of the device. Results. Four examples are presented from women undergoing evaluation of IUD placement in whom 2-dimensional ultrasonography failed to visualize the device satisfactorily. Volume contrast imaging in the C plane allowed visualization of the acoustic shadows of the IUDs, thereby providing more exact imaging of the type of device as well as aiding in locating the IUD. In a woman with irregular bleeding, a bicornuate uterus with pregnancy in 1 horn and a bowed T-type IUD in the contralateral horn were diagnosed with VCI-C. Conclusions. We conclude from these shadow images that VCI-C is a useful modality in cases of difficult visualization of the IUD; VCI-C visualization of the acoustic shadow of the IUD may provide an adjunctive approach.

Original languageEnglish
Pages (from-to)613-616
Number of pages4
JournalJournal of Ultrasound in Medicine
Volume25
Issue number5
DOIs
StatePublished - May 2006
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • 3-dimensional ultrasonography
  • Intrauterine device
  • Volume contrast imaging C plane

Fingerprint

Dive into the research topics of 'The shadow of the intrauterine device'. Together they form a unique fingerprint.

Cite this