Ultra-thin folded imager

E. J. Tremblay, J. Rutkowski, I. Tamayo, R. A. Stack, R. L. Morrison, D. Combs, J. Mader, H. C. Kim, U. Levy, Y. Fainman, J. E. Ford

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

We present the optical design of a wavefront coded ultra-thin visible-light camera with 35 mm focal length, 0.12 radian field of view, and 0.7 numerical aperture; folded into a 5 mm total physical track.

Original languageEnglish
Title of host publicationComputational Optical Sensing and Imaging, COSI 2005
PublisherOptical Society of America (OSA)
ISBN (Print)155752789X, 9781557527899
DOIs
StatePublished - 2005
Externally publishedYes
EventComputational Optical Sensing and Imaging, COSI 2005 - Charlotte, NC, United States
Duration: 6 Jun 20056 Jun 2005

Publication series

NameOptics InfoBase Conference Papers
ISSN (Electronic)2162-2701

Conference

ConferenceComputational Optical Sensing and Imaging, COSI 2005
Country/TerritoryUnited States
CityCharlotte, NC
Period6/06/056/06/05

Bibliographical note

Funding Information:
This work was supported by the Soonchunhyang University Research Fund.

Fingerprint

Dive into the research topics of 'Ultra-thin folded imager'. Together they form a unique fingerprint.

Cite this