T1 - Updating national diagnostic reference levels for adult cardiac interventional procedures in Switzerland
AU - Samara, Eleni Theano
AU - Ekeberg, Jonas
AU - Pamplona, Gustavo S.P.
AU - Stüssi, Anja
AU - Treier, Reto
AU - Riede, Florian
AU - Franzeck, Florian
AU - Bayard, Yves
AU - Steffen, Christian
AU - Nüssli, Dominique
AU - Salzberg, Sacha
AU - Pusterla, Orso
AU - Eggimann, Hannah
AU - Schegerer, Alexander
AU - Meier, Pascal
AU - Girod, Gregoire
AU - Petegnief, Yolande
AU - Menz, Roman
AU - Aberle, Christoph
AU - Spahiu, Valon
AU - Stortecky, Stefan
AU - Meyer, Matthias R.
AU - Merce, Marta Sans
AU - Viry, Anais
AU - Nowak, Marie
AU - Gallego-Manzano, Lucia
AU - Saltybaeva, Natalia
AU - Gotschy, Alexander
AU - Saguner, Ardan M.
N1 - Publisher Copyright:
Copyright © 2026. Published by Elsevier Ltd.
PY - 2026/8
Y1 - 2026/8
N2 - Diagnostic reference levels (DRLs) have been proven to be a useful tool for optimizing patient radiation exposure. National DRLs (NDRLs) are defined based on data from a representative sample of the healthcare facilities in a particular country. This project presents the survey to update the NDRLs for cardiac interventional procedures in Switzerland. Healthcare facilities performing cardiac procedures in Switzerland were asked to provide radiation dose data for adult cardiac interventional procedures performed over the course of one year. The dataset included the procedure name and the corresponding air kerma area product, air kerma at the reference point, fluoroscopy time and number of cine acquisitions. Thirty-five healthcare facilities (95% of the total) provided data. The procedures were grouped into 11 electrophysiology procedures, 4 cardiac catheterization procedures, and 3 structural heart procedures. For each healthcare facility and radiation quantity, the median values were calculated. Updated NDRLs were determined as the 75th percentile of the distribution of these median values. For example, the updated NDRL for air kerma area product was set at 24 Gy∙cm2 for coronary angiography and at 2 Gy∙cm2 for pacemaker implantation, reflecting a substantial reduction from the prior NDRL values of 50 and 30 Gy∙cm2, respectively. These new NDRL values are substantially lower than the previous ones, highlighting the importance of conducting regular updates to accommodate continuous patient dose optimization of and technological advancements.
AB - Diagnostic reference levels (DRLs) have been proven to be a useful tool for optimizing patient radiation exposure. National DRLs (NDRLs) are defined based on data from a representative sample of the healthcare facilities in a particular country. This project presents the survey to update the NDRLs for cardiac interventional procedures in Switzerland. Healthcare facilities performing cardiac procedures in Switzerland were asked to provide radiation dose data for adult cardiac interventional procedures performed over the course of one year. The dataset included the procedure name and the corresponding air kerma area product, air kerma at the reference point, fluoroscopy time and number of cine acquisitions. Thirty-five healthcare facilities (95% of the total) provided data. The procedures were grouped into 11 electrophysiology procedures, 4 cardiac catheterization procedures, and 3 structural heart procedures. For each healthcare facility and radiation quantity, the median values were calculated. Updated NDRLs were determined as the 75th percentile of the distribution of these median values. For example, the updated NDRL for air kerma area product was set at 24 Gy∙cm2 for coronary angiography and at 2 Gy∙cm2 for pacemaker implantation, reflecting a substantial reduction from the prior NDRL values of 50 and 30 Gy∙cm2, respectively. These new NDRL values are substantially lower than the previous ones, highlighting the importance of conducting regular updates to accommodate continuous patient dose optimization of and technological advancements.
KW - Cardiac interventional procedures
KW - Diagnostic reference levels
KW - National survey
UR - https://www.scopus.com/pages/publications/105043179060
U2 - 10.1016/j.ejmp.2026.105869
DO - 10.1016/j.ejmp.2026.105869
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 42378754
AN - SCOPUS:105043179060
SN - 1120-1797
VL - 148
JO - Physica Medica
JF - Physica Medica
M1 - 105869
ER -